High Pressure Switch with 1/4” Quick Connects
The High-Pressure Switch is designed to cut power to an attached booster pump/solenoid valve when the pressure exceeds approx 30-40 PSI and is suitable for both 24v and 30v systems. It comes with preinstalled connectors to enable connection to all Reef Pure RO System 24v and 30v pumps, power adapters and accessories.
Please Note: The High-Pressure switch is not designed to be operated with a float valve as the reduction in flow when close to closed will cause the switch to engage and disengage causing excessive wear.
Low Pressure Switch With 1/4″ Quick Connects
The Low Pressure Switch with 1/4″ Quick Connects is designed to cut power to an attached booster pump/solenoid valve when the supplied water pressure drops below approx 20-30 PSI and is suitable for both 24v and 30v systems. It comes preinstalled with a 1/4″ T fitting and power connectors to enable connection to all Reef Pure RO System 24v and 30v pumps, power adapters and accessories.
PurePro HF-8367 Pump Head
The PurePro HF-8367 Pump Head is the replacement pump head for the PurePro HF-8367 Pump.
PurePro HF-8367 RO Booster Pump
All RO membranes have an optimal minimum operating pressure. The PurePro RO membranes used in all Reef Pure RO Systems have an optimal minimum operating pressure of 50psi.
The system will operate below 50psi, however, the performance of your RO membrane will not be optimal. Your system will produce more wastewater and will also result in a higher TDS reading of your RO production water. This is due to a reduced salt rejection from your RO membrane. A higher TDS reading will also deplete your DI resin much quicker than a system producing low TDS water.
The great news is that it is simple to get your system running at the optimal pressure with one of our PurePro HF-8367 RO Booster Pump and will save you a small fortune in DI resin replacement costs.
Click here for user manuals, support information & product downloads
PurePro HF-8367 RO Booster Pump Upgrade Kit
This upgrade kit provides everything you need to upgrade your system with a booster pump and also have it automated by installing the Reef Pure RO Systems Auto Shut-Off Float Valve Upgrade Kit. The kit includes high and low-pressure switches giving your system the ability to detect when your water reservoir is full, disabling the booster pump accordingly.
All RO membranes have an optimal minimum operating pressure. The PurePro RO membranes used in all Reef Pure RO Systems have an optimal minimum operating pressure of 50psi.
The system will operate below 50psi, however, the performance of your RO membrane will not be optimal. Your system will produce more wastewater and will also result in a higher TDS reading of your RO production water. This is due to a reduced salt rejection from your RO membrane. A higher TDS reading will also deplete your DI resin much quicker than a system producing low TDS water.
The great news is that it is simple to get your system running at the optimal pressure with one of our PurePro HF-8367 RO Booster Pump and will save you a small fortune in DI resin replacement costs.
Click here to download the PurePro HF-8367 RO Booster Pump Upgrade Kit User Manual
PurePro HF-8380 High Flow Pump Head
The PurePro HF-8380 High Flow Pump Head is the replacement pump head for the PurePro HF-8380 High Flow Pump.
Solenoid Valve with 1/4″ Quick Connect Fittings
The Solenoid Valve with 1/4″ Quick Connects is a normally closed valve that opens to allow the flow of water when powered. It comes preinstalled with 1/4″ quick connect elbows and is designed to connect to all Reef Pure RO booster pumps, power adapters and pressure switches.