PRODUCT SPECIFICATIONS
Applied Pressure PSI(Bar) | Permeate Flow Rate GPD(L/H) | Stabilized Salt Rejection(%) |
80 (5.4) | 50 (7.9) | 98 |
1.Permeate flow and salt rejection based on the following test conditions: 250 ppm softened tap water, 77 F(25 C), 15% recovery and the specified applied pressure.
2.Minimum salt rejection is 96.0%.
3.Permeate flows for individual elements may vary +/-20%.
Dimensions | ||||
A | B | C | D | E |
298mm | 22mm | 17mm | 44.5mm | 254mm |
Operating Limits
Membrane Type: Polyamide Thin-Film Composite (TFC)
Maximum Operating Temperature: 45°C
Optimal Operating Pressure: 50psi to 100psi
Maximum Operating Pressure: 100 psi
Maximum Feed Flow Rate: 7.6 litres per minute
Free Chlorine Tolerance: <0.1 ppm
General Information
- The first 45 minutes of permeate/filtered water should be discarded. Do not use this initial permeate/filtered water for aquarium water.
- Keep membranes moist at all times after initial wetting, do not allow them to dry out.